Elcometer 510 kohvris paikuv kaasaskantav mõõteseade koos tarvikute ja vahtpolstriga

Adhesion Strength Testers

Elcometer 510 Automatic Adhesion Tester

The Elcometer 510 automatic "pull-off" adhesion tester accurately measures the adhesion strength of coatings on a wide range of substrates.

Automatic hydraulic pumpApplies smooth and continuous pressure, ensuring repeatable and reliable measurement results.
Preset drawing speedThe device automatically applies the predefined pull-off speed to obtain repeatable results.
Durable and waterproofImpact-resistant and dust- and water-resistant (IP64 rating), suitable for harsh conditions.
Data transmissionData transfer via USB and Bluetooth® to iOS and Android devices, compatible with ElcoMaster® software.

The Elcometer 510 automatic hydraulic adhesion tester accurately measures the adhesion strength of coatings on a wide range of substrates. The automatic hydraulic pump ensures smooth and continuous pressure application, resulting in repeatable and reliable measurement results.

Unlike many other instruments, the Elcometer 510 allows the pull-off rate to be preset, which the device then applies automatically. Suitable for both laboratory and field use.

Key benefits

Adjustable pull-off rates and automatic application for repeatable results

Interchangeable reusable dollies: 10, 14.2, 20 and 50 mm

Interchangeable units: MPa, psi, N/mm² and N

Data transfer via USB and Bluetooth® to iOS and Android devices

Compatible with free ElcoMaster® software for creating professional reports

Durable, shock-resistant and dust- and waterproof (IP64-equivalent), suitable for harsh conditions

Bright colour LCD screen with ambient light sensor, multilingual menu

Trend graphs, pull-off rate graphs and real-time statistics

On-site calibration check mode

Complies with national and international standards; recording of adhesive and cohesive failure attributes

Supplied in a robust plastic carry case; 2-year warranty

Application of pressureUp to 100 MPa (14,400 psi)
Pressure accuracy±1% täisskaalast
Pulling speed accuracy±(2,5% + 0,3 sekundit)
Pressure resolution0.01 MPa (1 psi)
Pull speed resolution0.01 MPa/s (1 psi/s)
Traction speed range0.02–5.6 MPa/s (depending on the die size)
Measuring range (10 mm)8–100 MPa
Measurement range (14.2 mm)4–50 MPa
Measuring range (20 mm)2–25 MPa
Measuring range (50 mm)0,3–4 MPa
Doll sizes10, 14.2, 20 and 50 mm
UnitsMPa, psi, N/mm² and N
MemoryUp to 60,000 measurements (Model T) / 60 measurements (Model S)
Number of batchesUp to 2,500 (Model T)
Dimensions260 × 100 × 66 mm
Weight2.9 kg (10/14.2/20 mm) to 3.1 kg (50 mm)
Power supply8 × AA batteries (16 rechargeable batteries and charger included) or mains power (Model T only)
Battery life~200 strokes per charge at up to 25 MPa at a rate of 1 MPa/s
Protection classIP64
Warranty1 year, extendable free of charge to 2 years within 60 days of purchase
Repeatable resultsAdjustable pulling speeds and automatic application ensure reliable and repeatable measurement results.
Professional reportsCompatibility with the free ElcoMaster® software enables the creation of professional reports.
Flexible useInterchangeable dies and units allow measurements to be adapted to different needs.
Standards-compliantComplies with national and international standards and records the adhesive and cohesive failure attributes.
Real-time overviewTrend graphs, tensile speed graphs and real-time statistics provide an immediate overview of measurements.
Laboritingimused
Välitingimused

Common questions about this product.

Frequently asked questions

What doll sizes does the device support and what are the corresponding measuring ranges?
The Elcometer 510 uses interchangeable, reusable dollies in sizes of 10, 14.2, 20 and 50 mm. The measuring ranges are respectively: 10 mm: 8–100 MPa; 14.2 mm: 4–50 MPa; 20 mm: 2–25 MPa; 50 mm: 0.3–4 MPa.
Is the device suitable for use in outdoor conditions and harsh environments?
Yes, the device is durable, shock-resistant, and dust- and water-resistant (IP64 rating), and is suitable for use both in the laboratory and in outdoor conditions.
What are the pressure accuracy and maximum pressure application of the device?
The device applies pressure up to 100 MPa (14,400 psi) with an accuracy of ±1% of full scale and a resolution of 0.01 MPa (1 psi).
How can measurement results be transmitted and reports generated?
Data can be transferred via USB and Bluetooth® to iOS and Android devices, and the device is compatible with the free ElcoMaster® software for creating professional reports.
How many measurements can the device's memory hold and how is the device powered?
The memory holds up to 60,000 measurements (Model T) or 60 measurements (Model S). Power supply is 8 × AA batteries (16 rechargeable batteries and charger included) or mains power (Model T only).

Need help finding the right solution?

We help you choose the solution that fits your needs and production.

Send request →
Quality materialsDurable industrial quality and long service life.
Experienced partnerWe help design, install and maintain.
Support & spare partsFast help and spare-part availability throughout the lifecycle.